Product Overview

The Paragon 8145-20 is a versatile electronic defrost timer designed for commercial freezers and refrigerators, providing automatic defrost capability with efficient operation and reliable performance.

The Paragon 8145-20 is a high-performance defrost timer designed specifically for commercial refrigeration systems. It provides automatic defrost control, ensuring efficient operation and preventing ice buildup in freezers and refrigerators. This timer is part of the 8000 Series, known for its reliability and durability in demanding environments. It supports both electric and hot gas defrost systems, making it versatile for various applications. The 8145-20 operates on 208-240V systems and is engineered to integrate seamlessly with existing compressors and heating elements. Its robust design ensures long-lasting performance, making it a trusted solution for commercial refrigeration needs.

1.2. Key Features and Applications

The Paragon 8145-20 defrost timer offers precise control for commercial refrigeration systems, supporting both electric and hot gas defrost methods. Designed for 208-240V operation, it is ideal for industrial freezers and refrigerators. Its key features include automatic defrost cycling, compatibility with compressors, and seamless integration with heating elements. This timer is widely used in commercial settings where reliable defrost control is crucial. Its versatility and durability make it a preferred choice for maintaining optimal refrigeration performance in demanding environments.

Technical Specifications

The Paragon 8145-20 is a high-performance defrost timer designed for 208-240V operation, offering precise control for commercial refrigeration systems with robust construction and reliable functionality.

2.1. Voltage and Power Ratings

The Paragon 8145-20 defrost timer operates at 208-240V, ensuring compatibility with commercial refrigeration systems requiring high voltage. It is designed for single-phase power systems, making it suitable for a wide range of applications. The timer’s robust design allows it to handle the power demands of electric heat defrosting systems efficiently. Its voltage and power ratings are optimized for reliable performance in industrial and commercial settings, ensuring precise control over defrost cycles. The unit is built to withstand the rigors of continuous operation, providing consistent and durable functionality for refrigeration and freezer systems.

2.2. Defrost Cycle Timing and Configuration

The Paragon 8145-20 defrost timer allows precise configuration of defrost cycles, with timing set via the timer wheel. Users can select the defrost cycle start time and duration by adjusting the wheel’s tripper positions. The timer supports both electric heat defrosting and hot gas systems, offering flexibility for different applications. The defrost cycle typically ranges from 4 to 110 minutes, depending on the system requirements. Terminal 3 provides power during the defrost cycle, while Terminal 4 remains inactive, ensuring proper control and safety. This configuration ensures efficient and reliable defrost operations in commercial refrigeration systems.

Installation and Wiring

The Paragon 8145-20 defrost timer must be installed according to the provided wiring diagram, ensuring proper connections to the compressor and heating systems for safe and efficient operation.

3.1. Step-by-Step Installation Guide

To install the Paragon 8145-20 defrost timer, begin by mounting it securely near the controlled equipment. Connect the line voltage (208-240V) to terminals L1 and L2, ensuring proper grounding. Next, wire the compressor and heater circuits according to the provided wiring diagram. Connect terminal 1 (L/L1) to the compressor and terminal 4 (L/L1) to the heater. Set the timer wheel to the desired defrost cycle and ensure all connections are tight. Refer to the manual for specific configurations and test the system to confirm proper operation.

3.2. Understanding the Wiring Diagram

The wiring diagram for the Paragon 8145-20 defrost timer is essential for proper installation. Terminal 1 (L/L1) connects to the compressor, while terminal 4 (L/L1) connects to the heater. Terminals L1 and L2 are for the 208-240V line voltage input. The neutral (N) and ground connections ensure safe operation. Refer to the diagram to configure SPDT thermostat wiring and defrost cycle settings. Verify all connections match the manual’s specifications to avoid malfunctions. Proper wiring ensures the timer accurately controls defrost cycles, compressor shutdown, and heater activation during defrost phases. Always test connections before powering up the system.

Operation and Functionality

The Paragon 8145-20 defrost timer automates defrost cycles, ensuring efficient operation. It integrates with compressors and heating systems, providing precise control over defrost timing and functionality;

4.1. Defrost Cycles and Timer Wheel Settings

The Paragon 8145-20 defrost timer manages defrost cycles by setting specific start times on the timer wheel. Users can slide the tripper upward to select the desired defrost cycle start time. The timer offers flexible scheduling, allowing for precise control over defrost operations. It supports both electric and hot gas defrost systems, ensuring compatibility with various commercial refrigeration setups. The timer wheel is divided into 24-hour segments, enabling easy customization of defrost intervals. This feature ensures efficient defrosting while minimizing operational downtime. The device automatically engages and disengages the defrost cycle based on the configured settings, optimizing system performance and energy use.

4.2. Interaction with Compressor and Heating Systems

The Paragon 8145-20 defrost timer seamlessly interacts with compressor and heating systems to ensure efficient defrosting. During the defrost cycle, the timer shuts down the compressor to prevent unnecessary operation. It then activates the heating elements to melt ice buildup. The timer’s design ensures that heating and compressor systems operate in harmony, preventing simultaneous activation. Terminals like L1, L2, and N are used to connect the compressor and heating systems, while terminals 3 and 4 manage power during the defrost cycle. This coordination optimizes energy use and maintains system performance, ensuring reliable operation in commercial refrigeration settings.

Troubleshooting and Maintenance

The Paragon 8145-20 defrost timer requires regular maintenance to ensure proper function. Check connections, test terminals for power, and verify wiring accuracy. Consult the manual for troubleshooting common issues like faulty cycles or power loss. Perform routine inspections and clean contacts to maintain reliability.

5.1. Common Issues and Solutions

Common issues with the Paragon 8145-20 defrost timer include no power to the unit, incorrect defrost timing, or relay failure. Check terminal connections for power and ensure wiring matches the diagram. If the timer does not cycle, verify the manual override switch is in the correct position. For relay issues, test for continuity and replace if faulty. Consult the manual for detailed troubleshooting steps and solutions. Regularly cleaning contacts and verifying settings can prevent operational disruptions. Always refer to the manual for specific guidance on resolving issues effectively. Proper maintenance ensures reliable performance.

5.2. Regular Maintenance Tips

Regular maintenance of the Paragon 8145-20 defrost timer ensures optimal performance and longevity. Clean the timer’s terminals and contacts periodically to prevent corrosion and ensure proper electrical connections. Inspect the wiring for any signs of damage or wear, and replace it if necessary. Lubricate the timer’s mechanical components as recommended in the manual to maintain smooth operation. Check the defrost cycle settings to ensure they align with your equipment’s requirements. Power cycle the timer monthly to reset its internal mechanisms. Refer to the manual for specific maintenance schedules and procedures. Proper care helps prevent malfunctions and extends the timer’s lifespan.

Safety Considerations

Adhere to the Paragon 8145-20 manual for safe operation. Ensure proper handling of 208-240V electrical connections and follow installation guidelines to prevent hazards and ensure reliable performance.

6.1. Electrical Safety Precautions

Always follow the Paragon 8145-20 manual for electrical safety. Ensure proper handling of 208-240V connections to avoid shock or damage. Disconnect power before installation or maintenance. Verify system grounding to prevent hazards. Never modify the timer or wiring without authorization. Use approved components and avoid overloading circuits. Keep the device away from water and flammable materials. If unsure, consult a licensed electrician. Regularly inspect wiring and connections for wear or damage. Adhere to local electrical codes for safe operation. Proper precautions ensure reliable performance and user safety.

6.2. Proper Handling and Storage

Handle the Paragon 8145-20 timer with care to avoid physical damage. Store it in a dry, cool environment, away from direct sunlight and moisture. Avoid exposing the device to extreme temperatures or humidity. Keep the timer in its original packaging or a protective case when not in use. Ensure all electrical components are secure to prevent damage during transport. Before installation, inspect the timer for any visible damage or wear. Clean the device regularly with a soft cloth to maintain performance. Always follow the manufacturer’s guidelines for storage and handling to ensure optimal functionality and longevity.

Comparison with Other Models

The Paragon 8145-20 stands out for its 208-240V compatibility and electric heat defrosting, differing from models like 8045-20, which support hot gas systems and 50Hz operation.

7.1. Differences Between 8145-20 and Other Defrost Timers

The Paragon 8145-20 defrost timer is distinct due to its 208-240V compatibility, electric heat defrosting capability, and specific terminal configurations. Unlike the 8045-20, it doesn’t support hot gas systems or 50Hz operation, making it specialized for electric heat applications. The 8145-20 features a manual override switch for maintenance, a unique aspect compared to other models. Its terminal setup, with power on terminal 3 during defrost and none on terminal 4, differs from other timers, which may have varying configurations. This specialization makes the 8145-20 efficient for specific tasks but less flexible overall compared to more versatile models.

7.2. Choosing the Right Model for Your Needs

When selecting a defrost timer, consider your system’s voltage requirements, defrost method, and operational needs. The 8145-20 is ideal for 208-240V systems with electric heat defrosting, offering precise timing and a manual override feature for maintenance. For applications requiring hot gas defrosting or 50Hz compatibility, alternative models like the 8045-20 may be more suitable. Always consult the product manual to ensure compatibility with your specific setup. This ensures optimal performance and avoids potential issues, making it crucial to match the timer’s specifications with your system’s demands for reliable operation.

Manual and Resources

Access the 8145-20 manual online for detailed setup and operation guides. Additional resources include wiring diagrams and troubleshooting tips for optimal performance.

8.1. How to Access the 8145-20 Manual

To access the 8145-20 manual, visit the official Paragon website or authorized distributors. Search for “Paragon 8145-20 manual” online to find downloadable PDF versions. Ensure the document is genuine by verifying the SUPCO Paragon Precision logo. If unavailable, contact Paragon customer support or check with suppliers like Grainger or McMaster-Carr. The manual provides essential setup, wiring, and troubleshooting details. Always refer to the official manual for accurate information to ensure proper installation and operation of the defrost timer.

8.2. Additional Resources for Setup and Operation

For comprehensive setup and operation guidance, refer to the official Paragon 8145-20 manual, available on their website or through authorized distributors. Additional resources include wiring diagrams, troubleshooting guides, and installation tutorials from SUPCO or Paragon Precision. Online forums and technical support from Paragon can address specific queries. Retailers like Grainger or McMaster-Carr often provide supplementary materials. Ensure all resources are from verified sources to maintain accuracy. These tools help users optimize the defrost timer’s performance and resolve potential issues efficiently. Always consult trusted sources for reliable information.

Wiring diagrams and operation guides are also available online, ensuring proper installation and functionality.

Leave a Reply

Related Post